•  Retrait gratuit dans votre magasin Club
  •  7.000.000 titres dans notre catalogue
  •  Payer en toute sécurité
  •  Toujours un magasin près de chez vous     
  •  Retrait gratuit dans votre magasin Club
  •  7.000.000 titres dans notre catalogue
  •  Payer en toute sécurité
  •  Toujours un magasin près de chez vous
  1. Accueil
  2. Livres
  3. Sciences humaines
  4. Sciences
  5. Chimie
  6. Chimie analytique
  7. Production of Colloidal Biogenic Selenium and Removal by Different Coagulation-Flocculation Approaches

Production of Colloidal Biogenic Selenium and Removal by Different Coagulation-Flocculation Approaches

Lucian C Staicu
Livre relié | Anglais | Ihe Delft PhD Thesis
93,45 €
+ 186 points
Format
Livraison 1 à 2 semaines
Passer une commande en un clic
Payer en toute sécurité
Livraison en Belgique: 3,99 €
Livraison en magasin gratuite

Description

Selenium (Se) is a chemical element of concern due to its toxicity and increasing anthropogenic release to the environment. Se oxyanions, selenite and selenate, are water-soluble, bioavailable and toxic, whereas elemental selenium, Se(0), is solid and less toxic. Nevertheless, Se(0) is potentially harmful as particulate Se(0) has been reported to be bioavailable to bivalves, to fish and also prone to re-oxidation. In the current work we investigated the reduction of selenite and selenate using pure and mixed microbial cultures. A novel strain of Pseudomonas moraviensis showing high Se tolerance was isolated, classified and characterized for the first time. Biogenic Se(0) shows colloidal properties due to its nanosize scale and negatively-charged biopolymer coating. To address the need for efficient solid-liquid separation of biogenic Se(0) prior to environmental discharge, we tested and compared several physical-chemical separation methods. Centrifugation and filtration can be efficiently used for Se(0) separation but they are not feasible at the industrial scale due to prohibitive costs. Alternatively, chemical coagulation by metal salts, e.g. aluminum sulfate and ferric chloride, resulted in high removal rates around 90%. Electrocoagulation reached the highest colloidal Se(0) removal efficiency of 97% when using iron electrodes. In conclusion, biogenic Se(0) must be removed in a biological post-treatment step and several approaches described in this work could be successfully used.

Spécifications

Parties prenantes

Auteur(s) :
Editeur:

Contenu

Nombre de pages :
148
Langue:
Anglais
Collection :

Caractéristiques

EAN:
9781138373327
Date de parution :
27-09-18
Format:
Livre relié
Format numérique:
Genaaid
Dimensions :
170 mm x 240 mm
Poids :
452 g

Les avis