•  Retrait gratuit dans votre magasin Club
  •  7.000.000 titres dans notre catalogue
  •  Payer en toute sécurité
  •  Toujours un magasin près de chez vous     
  •  Retrait gratuit dans votre magasin Club
  •  7.000.000 titres dans notre catalogue
  •  Payer en toute sécurité
  •  Toujours un magasin près de chez vous

Low-Level Hexavalent Chromium Treatment Options

Bench-Scale Evaluation

P Brandhuber, M Frey, M McGuire
Livre broché | Anglais | Water Research Foundation Report
177,45 €
+ 354 points
Livraison sous 1 à 4 semaines
Passer une commande en un clic
Payer en toute sécurité
Livraison en Belgique: 3,99 €
Livraison en magasin gratuite

Description

In February 1999, the California Office of Environmental Health Hazard Assessment issued a Public Health Goal (PHG) for total chromium of 2.5 µg/L. The PHG, based on a 10^6 risk level for 0.2 µg/L hexavalent chromium [Cr(VI)], was 40 times less than the USEPA's contaminant MCL of 100 µg/L for total chromium [Cr(III) ] Cr(VI)]. The success of the movie Erin Brockovich, which popularized a groundwater chromium pollution lawsuit in Hinkley, California, sensitized the public to the health hazards of chromium in drinking water. In 2001, the California state legislature passed a bill requiring the California Department of Health Services to adopt an MCL for Cr(VI). All of these actions must be viewed from the perspective that, at the time, no technology had been demonstrated to be effective at treating chromium to concentrations consistent with the total chromium PHG or the Cr(VI) 10^6 risk level of 0.2 µg/L. The purpose of this report was to present the results of this partnership study, which included an analysis of chromium occurrence and co-occurrence, an evaluation of Cr(VI) removal technologies, and an examination of chromium oxidation and reduction chemistry. This study investigated nearly all of the potential methods of controlling Cr(VI) either through the use of technologies that remove Cr(VI) directly (adsorption, anion exchange, membrane filtration) or those that remove the reduced form of chromium, Cr(III) (precipitation with membranes or coagulation and precipitation with conventional or membrane filters). These technologies were investigated using laboratory-scale testing methods, including batch isotherm tests, bench membrane systems, flow-through mini-columns, and jar testing techniques. For most technologies, controlled water matrices were used to screen performance. Selected technologies were further assessed using natural groundwater matrices from the Los Angeles Department of Water and Power and the Glendale Water and Power groundwater facilities.

Spécifications

Parties prenantes

Auteur(s) :
Editeur:

Contenu

Nombre de pages :
212
Langue:
Anglais
Collection :

Caractéristiques

EAN:
9781843399247
Date de parution :
14-07-05
Format:
Livre broché
Format numérique:
Trade paperback (VS)
Dimensions :
210 mm x 279 mm
Poids :
489 g

Les avis